Skip to main content
Version: 1.2

Visual Editor

The Visual Editor is used to define your specification, configuration and any other options.

Opening the Editor​

The Visual Editor is only available when your report is in edit mode, that is, when you're editing in Power BI Desktop or in the Service. If the report is being viewed in the Power BI Service or other application, then it is not eligible for editing and any such options will be unavailable to your end-users.

To use the editor, your visual first needs some data, so please ensure that you have added any appropriate columns or measures to the Values data role.

Once data has been provided, the Visual Editor is accessed by selecting the visual header (...) and then Edit, e.g.:

Opening the Visual Editor from the visual header.

This will put the visual into focus mode and display the Visual Editor for you to begin creating or amending your specification.

Finding your Way Around​

By default, the Visual Editor pane will be on the left and your rendered specification will be shown in a preview area to the right, e.g.:

Overview of the Visual Editor.

Here's One We Made Earlier

We're showing a pre-built specification here; if this is your first time opening the editor in a new visual, then the New Specification dialog will be visible, to help you get started. Refer to the Simple Worked Example page for an example of this functionality, or the New Specification section below for more details.

Preview Area​

Deneb captures the dimensions of your visual prior to opening the Visual Editor and shows this at 100% scale. This is so that you know how your design should look within the confines of the visual viewport when you return to the report.

The dashed line represents the boundaries of your visual in standard view. Power BI does not allow visuals to resize themselves dynamically, so if you wish to change the physical width and/or height of your visual in the report view, you will need to exit the advanced editor, resize and re-open the advanced editor.

Your visual may not fit entirely into the preview area at 100% scale, so you can use the zoom controls in the preview area toolbar to adjust this accordingly, or resize (or minimize) the editor pane to accommodate.

If you would prefer to not see the boundary marker, you can disable this in the properties pane by selecting Editor > Show Boundary Marker > OFF in the Power BI Format pane:

The Show Boundary Marker property in the Format pane.

Toolbar​

The preview area toolbar, in the bottom-right of the Visual Editor's preview pane.

The preview area also contains a toolbar, which provides additional controls to assist with detail work. From left to right these are:

  • Specification provider and version.

    Check the Provider Version Can Do What You're Looking Up

    Deneb doesn't automatically support new releases of Vega or Vega-Lite. Because the runtimes are embedded, any new releases need to be be tested, implemented and deployed to AppSource, which can take some time. As such, you can use this information in the toolbar to confirm if the embedded version might be behind any new features published by the Vega team.

  • Zoom preview out by 10% ( Ctrl + Alt + - )

  • Zoom level slider - allows manual adjustment of zoom level from 10% to 300%.

  • Zoom preview out by 10% ( Ctrl + Alt + + )

  • Zoom preview to actual size ( Ctrl + Alt + 0 )

  • Zoom preview to fit available space ( Ctrl + Alt + * )

Editor Pane Position​

If you prefer your editor on the right, you can modify this in the properties pane by selecting Editor > Position > Right in the Power BI Format pane:

The editor Position property in the Format pane.

JSON Editor Font Size​

The size of the font used for editing JSON can be modified by selecting Editor > JSON Editor Font Size in the Power BI Format pane:

The JSON Editor Font Size property in the Format pane.

Word Wrap​

By default, any content in the editor that overflows the width will wrap onto a new line. By disabling the Editor > Word Wrap property in the Power BI Format pane, you can keep content on a single line, and the editor will display a horizontal scrollbar as appropriate.

Line Gutter & Line Numbers​

By default, the editor will show line numbers in the left-hand gutter.

  • You can disable this gutter by disabling the Editor > Line Gutter property in the Power BI Format pane.
  • Alternatively, you can keep the gutter (so that sections of JSON can still be expanded and collapsed as needed) but hide the line numbers by disabling the Editor > Line Numbers property.

The Visual Editor Pane​

The Visual Editor pane is used to carry out any operations in this screen:

  • It can be collapsed and expanded, much like the other panes in Power BI, which can be useful for previewing designs.
Keyboard shortcut for collapse/expand:

[ Ctrl + Alt + Space ]

  • The pane can be resized to use a maximum of 60% of the visible canvas by click-dragging.
  • Double-clicking the resizer will revert the pane to its default size (40% of the visible canvas).

The editor pane can be dragged to resize, or reset by double-clicking the resizer.

The Command Bar​

Command bar icons.

The Command Bar contains the following operations (from left to right):

Apply (Ctrl + Enter)​

  • Selecting this option will apply any changes you have made in either the Specification or Config and update your visual.
  • This option is disabled if you have Auto-Apply enabled (see below).
Apply Often

If you exit focus mode (and out of the Visual Editor) any unapplied changes may not be saved, so please ensure that you apply changes before returning to the standard view. Refer to the Unapplied Changes section below for more details as to how you can mitigate this.

Toggle Auto-Apply (Ctrl + Shift + Enter)​

  • Selecting this option will apply changes to the Specification or Config editors as you type them.
  • Enabling this option will disable the Apply command.
Consider Performance

Whilst this option is convenient for seeing changes take effect immediately, it can have negative performance implications if you're working with a large number of data points or elements within your visualization. Please refer to the Performance Considerations page for further details on potential risks and mitigation approaches.

Repair and Format JSON (Ctrl + Alt + R)​

  • Selecting this option will attempt to repair any simple typographical issues in your JSON, and re-format it with indentation.
  • The tooling does its best to fix anything straightforward but in some cases it will not be possible to repair the JSON and manual corrections may be required and a banner will be shown above the editor.
  • In these cases, you can select the error details in the bottom-right to investigate further and use this information to correct, e.g.:

If the Repair and Format JSON command cannot parse the JSON, you can investigate using the error details.

Edit Specification Field Mapping (Ctrl + Alt + F)​

  • Selecting this option allows you to re-assign any columns or measures that are bound to an encoding or expression in your specification.
  • This is documented in more detail on the Dataset page.

New Specification (Ctrl + Alt + N)​

  • Selecting this option will open the Create New Specification dialog.
  • The dialog can be used to replace the current Specification and Config with either an bare-minimum set of JSON for each, or you can choose from a number of simple templates to get started.
  • Templates are currently packaged in with the visual and it's not yet possible to import them, although hopefully this will be something we can work on bringing in later on.
First Time Use

This dialog is also displayed by default if this is the first time opening the Visual Editor for any new instance of Deneb that you add to the report canvas.

Generate JSON Template (Ctrl + Alt + E)​

  • Selecting this option will open the Generate JSON Template dialog.
  • The dialog can be used to create an exportable version of the your specification. Refer to the appropriate section in the Templates page for more information on usage.

Help (Ctrl + Alt + H)​

  • Selecting this option will cause Power BI to confirm you wish to open the link to this documentation site. Selecting OK will open it in a new browser tab.

Specification Editor Tab​

Keyboard shortcut

[ Ctrl + Alt + 1 ]

  • This tab contains an editor that you can use to enter and amend your specification's JSON as desired.
  • To view the results of your changes, you can either Apply your changes, or ensure that Auto-Apply is enabled.
  • The JSON must produce a valid specification for your selected provider (either Vega or Vega-Lite).
  • The editor will perform validation against the schema for the specified provider and warnings are displayed that you can inspect, e.g.:

The Specification editor will validate your JSON against the Vega or Vega-Lite language schema, as appropriate.

Config Editor Tab​

Keyboard shortcut

[ Ctrl + Alt + 2 ]

  • This tab contains an editor that you can use to enter and amend any JSON you wish to add for your visual's config as desired.
  • To view the results of your changes, you can either Apply your changes, or ensure that Auto-Apply is enabled.
  • The JSON must produce a valid config for your selected provider (either Vega or Vega-Lite).
  • It's generally advised to try and use the config for anything that can "theme" your chart and keep this separate from the specification. This makes easier to port across to other instances of the visual, e.g.:

Example of Config editor content. This allows you to alter cosmetic aspects of your visual specification.

Settings Tab​

Keyboard shortcut

[ Ctrl + Alt + 3 ]

  • This tab is used to configure specific behavior of Deneb when generating output:

The Settings pane in the Visual Editor.

  • The Provider section allows you to specify whether to use Vega or Vega-Lite for your Specification and Config.
    • Vega-Lite is much simpler for newcomers as it is much more concise and abstracts away a lot of the things that you would normally need to prescribe when using Vega.
    • Vega does provide a lot more in the way of control over your visualization at the cost of a higher-learning curve.
  • The Render Mode section specifies whether to use either Vega's SVG renderer or Canvas renderer when compiling, parsing and producing your design.
    • Canvas renders your design as pixel graphics.
    • SVG creates your design from vector graphics, results in a number of component elements within the visual to produce the output.
    • Please refer to the Performance Considerations page for further details on potential risks and mitigation approaches when it comes to selecting a renderer.
  • The Vega > Power BI Interactivity section specifies which interactivity features to enable.
    • As these require some additional setup in your specification, as well as some internal logic to link everything together you are able to specify whether they should be set-up or not.
    • Please refer to the Interactivity Features and related pages (Tooltips | Context-Menu | Cross-Filtering | Cross-Highlighting) for further details on how to configure these for your specification.

Column and Measure Completion​

Specification editor only

As the specification is text-based, it can be onerous to look-up or type the names for measures or columns in manually. For any that are added to the Values data role, they will be offered (along with a qualifier as to their type) in the Specification editor’s auto-completion, e.g.:

Example of auto-completion from the visual dataset.

Unapplied Changes​

If you've made changes in the Visual Editor and select Back to report without applying them, you will get a prompt alerting you of this:

The 'Unapplied Changes' dialog attempts to allow you to save any changes made in the editor before they can be lost.

caution

This is a 'last chance' to make sure that any changes you want to keep are applied. If changes are discarded, they cannot be recovered.